Pressure regulating valve, STE

C04V3, Pilot Operated, Spool-Type with Relieving

Features

  • Maximum pressure setting up to 350 bar.
  • Low pressure rise/flow characteristic
  • Spool valve for good stability
  • Partial reverse flow capability
  • Hardened working parts for maximum durability

 

Operation

The adjustable spring-loaded ball in the pilot section is shifted at valve setting by the regulated outlet pressure sensed through an orifice in the main spool from port [3]. The resulting pilot flow creates a pressure drop across the spring-loaded main spool that then meters the supply flow from port [2], maintaining the regulated pressure on port [3]. An increase in the regulated pressure causes the spool to lift further and acts as a service line relief valve, closing the supply port [2] and then relieving to port [1]. Ports [2] and [3] remain normally open when port [3] pressure is below the valve setting.

Back pressure on port [1] adds to the valve setting.

 

Application note

  • Drain line should be piped directly to the tank. Any back pressure in the drain line will be additive to the regulated pressure.

Partnumber:
C04B3MZN

Package size:
0 pcs

Min. order quantity is:
1 pcs
Valve Block alu. 3/8 (CAV04-
Partnumber: 716A
Valve Block steel 3/8 (cav04-3)
Partnumber: 716S
Valve Block steel 1/2 (cav04-3)
Partnumber: 716S-1/2
Valve Block steel 3/4 (cav04-3)
Partnumber: 716S-3/4
Seal kit for Sterling valve
Partnumber: SK30505N-1
Brand Name
Hydraspecma

Cavity
CAV04-3

Contamination level max.
18/16/13 - ISO 4406

Flow rate nominal LMin
120 lpm

Oil viscocity recommended
15 - 50 cSt

Pressure max.
420 bar

Pressure setting max.
350 bar

Pressure setting min.
10 bar

Sealing material
NBR

Torque tightening
50 Nm
Package size
0 pcs

Barcode
5704295406312

Gross weight
0,24 Kg

Net weight
0,24 Kg

Country of origin
GBR

Intrastat code
84812010

C04V3, Pilot Operated, Spool-Type with Relieving

Features

  • Maximum pressure setting up to 350 bar.
  • Low pressure rise/flow characteristic
  • Spool valve for good stability
  • Partial reverse flow capability
  • Hardened working parts for maximum durability

 

Operation

The adjustable spring-loaded ball in the pilot section is shifted at valve setting by the regulated outlet pressure sensed through an orifice in the main spool from port [3]. The resulting pilot flow creates a pressure drop across the spring-loaded main spool that then meters the supply flow from port [2], maintaining the regulated pressure on port [3]. An increase in the regulated pressure causes the spool to lift further and acts as a service line relief valve, closing the supply port [2] and then relieving to port [1]. Ports [2] and [3] remain normally open when port [3] pressure is below the valve setting.

Back pressure on port [1] adds to the valve setting.

 

Application note

  • Drain line should be piped directly to the tank. Any back pressure in the drain line will be additive to the regulated pressure.