Flow Cont. valve 11,4l/m (0.4-11l/m) HFCV10-RT-P-E-4.0-00

This is a fully adjustable, restrictive type, pressure compensated flow control valve from port 1 to 2 with a reverse free flow check from port 2 to 1. The flow from port 2 will remain constant regardless of the pressure difference across the valve.

Flow enters at port 1 and passes across an adjustable orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Flow from port 2 to 1 passes freely across an integral check valve.

Partnumber:
83027758

Package size:
0 pcs

Min. order quantity is:
1 pcs
Mix-N-Match Dual Cross Body 1/2"DCP10-2-4B
Partnumber: 11135684
Mix-N-Match Dual Parallel Body 1/2"DPL10-2-4B
Partnumber: 11137221
Housing SDC10-2-S3B steel 3/8
Partnumber: 11143048
Housing SDC10-2-S4B steel 1/2 port
Partnumber: 11143049
Housing SDC10-2--LG14B (1/2)
Partnumber: 922514110
Housing SDC10-2--LG24B (1/2)
Partnumber: 922514210
HOUSING, SDC10-2-DG3B (3/8) SDC10-2-DG3B (3/8)
Partnumber: 922516910
HOUSING, SDC10-2-DG4B (1/2) SDC10-2-DG4B (1/2)
Partnumber: 922517010
Brand Name
Danfoss

Cavity
SDC10-2

Contamination level max.
20/18/14 - ISO 4406

Flow max. regulated
11 lpm

Flow min. regulated
0.4 lpm

Flow rate nominal LMin
12 lpm

Model code
HFCV10-RT-P-E-4.0-00

Oil viscocity recommended
12 - 54 cSt

Pressure compensated
Yes

Pressure max.
350 bar

Temperature max.
+100 °C

Temperature min.
-40 °C

Torque tightening
68 - 75 Nm
Package size
0 pcs

Barcode
5704334468233

Gross weight
0,17 Kg

Net weight
0,17 Kg

Country of origin
ITA

Intrastat code
84812010

This is a fully adjustable, restrictive type, pressure compensated flow control valve from port 1 to 2 with a reverse free flow check from port 2 to 1. The flow from port 2 will remain constant regardless of the pressure difference across the valve.

Flow enters at port 1 and passes across an adjustable orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Flow from port 2 to 1 passes freely across an integral check valve.